Sample dataQuality assurance and in-process inspection
Measuring equipment control
What we measure with, how long the calibration holds, and what must not be picked up right now.
68
Gauges on the register
12 of them kept in the metrology room
3
Calibration due within 7 days
deadlines between 3 and 6 Aug
2
Blocked
past the deadline or away at the calibration lab
9
Calibrations planned for August
4 of them external
- All
- Due within 30 days
- Blocked
- Externally calibrated
- Metrology room
Measuring equipment
Traceability to national standards through each provider's calibration certificate. Blocked gauges cannot be selected in an inspection record.
| Number | Equipment | Range | Location | Last calibration | Next calibration | State |
|---|---|---|---|---|---|---|
| PM-041 | EquipmentDigital calliper 150 mm | Range0 – 150 mm | LocationTurning, BAZ-04 | Last calibration05.02.26 | Next calibration05.08.26 | StateDue in 5 days |
| PM-058 | EquipmentDial indicator 0.01 mm with magnetic stand | Range0 – 10 mm | LocationMilling | Last calibration30.01.26 | Next calibration30.07.26 | StateOverdue, blocked |
| PM-089 | EquipmentThread plug gauge M8 – 6H, go/no-go | RangeM8 – 6H | LocationMetrology room | Last calibration12.03.26 | Next calibration12.09.26 | StateValid |
| PM-092 | EquipmentGauge block set, 47 pieces | Range0.5 – 100 mm | Locationat the calibration lab | Last calibration11.07.25 | Next calibration11.07.26 | StateExternal, blocked since 14 Jul |
| PM-114 | EquipmentThree-point bore gauge | Range20 – 25 mm | LocationMetrology room | Last calibration04.03.26 | Next calibration04.09.26 | StateValid |
| PM-133 | EquipmentOptical comparator, 10× | Range0 – 50 mm | LocationMetrology room | Last calibration03.02.26 | Next calibration03.08.26 | StateDue in 3 days |
| PM-166 | EquipmentRoughness tester, stylus type | RangeRa 0.02 – 10 µm | LocationMetrology room | Last calibration06.02.26 | Next calibration06.08.26 | StateDue in 6 days |
| PM-207 | EquipmentMicrometer 25 – 50 mm | Range25 – 50 mm | LocationMetrology room | Last calibration22.02.26 | Next calibration22.08.26 | StateValid |
| KMG-02 | EquipmentCoordinate measuring machine, bridge type | Range900 × 600 × 500 mm | LocationMetrology room | Last calibration16.06.26 | Next calibration16.06.27 | StateValid |
9 of 68 gauges · filter: due within 30 days or overdue
Calibration dates, week 32
Internal appointments in the metrology room, external items collected by the calibration lab.
Mon 3 Aug
7:00 AM
PM-133 optical comparator
internal, metrology room — deadline falls today
Tue 4 Aug
9:00 AM
Collection by the calibration lab
PM-058 and four further dial indicators
1:00 PM
Repeat measurement of M04
batch CH-2026-0771 after re-clamping, on KMG-02
Wed 5 Aug
7:30 AM
PM-041 calliper
internal, metrology room — deadline falls today
Thu 6 Aug
8:00 AM
PM-166 roughness tester
external, on site, service engineer
2:00 PM
PM-092 gauge block set returns
check the certificate, file the traceability record
Fri 7 Aug
10:00 AM
Stocktake, metrology room
12 items, location and identification
How Awelior would approach this project
Fairbridge Precision Engineering Inc. is invented — the way it is built is not. None of this is work delivered for a client. It is the shape we would give such a project — with the same depth, but without a client who would have to answer for it.
Where it starts
Fairbridge Precision Engineering Inc. inspects in production and documents on paper. Inspection plans live in a spreadsheet, the calibration list is taped to the metrology room door. As long as nothing is challenged that is enough; once a complaint arrives, somebody has to work backwards from the batch through the order to the measurement record — and that path does not exist in a binder.
Decisions
Traceability down to the batch as the ground plan
Inspection order, record, nonconformity and measuring equipment hang on the same chain. That is not one feature among many but the arrangement every other screen follows from.
A nonconformity is a case of its own
A rejection does not end with a red field in the record; it becomes a case with cause, action and effectiveness check. Without that a quality system is a collection of measurements.
Measuring equipment with calibration dates in the system
A caliper whose calibration has lapsed makes every record produced with it contestable. The list on the door knew that too — the record did not.
Deliberately left outNo connection to measuring machines and no statistical process control. Both are the next step and assume the inspection processes are cleanly in the system first — otherwise a control chart gets drawn from values whose origin nobody can evidence.
What is in it
- Screens
- 5
- Content blocks
- 19
- Languages
- 4
Five screens, in all four languages, with sidebar, header and stated role. Navigation works; tables, filters, board, calendar, step chains, history and single records are rendered and inert. Orders, batches and measurements are invented.
How it would go on
Instruments and data capture
Typing measurements in by hand is the most common source of error. Connecting the instruments saves errors rather than time.
Standards and audits
What an auditor wants to see shapes the structure: evidence trails, approvals, document control and the question of who may change what.
Connection to production
Inspection orders arise from production orders. Without that link somebody creates every inspection order by hand — and forgets exactly the ones that matter.